- Medical Consumables[10]
- Gas Analyzers[2]
- Laboratory Heating Equipments[1]
- Other Lab Supplies[10]
- Other Measuring & Analysing Instruments[4]
- Ice Makers[6]
- Ice Crushers & Shavers[1]
- Laboratory Centrifuge[5]
- Fiber Optic Equipment[1]
- Oscillators[2]
- Weighing Scales[4]
- Laboratory Furniture[1]
- Laboratory Bottle[4]
- Other Office & School Supplies[7]
- Filter Papers[1]
- Food Additives[1]
- Bottles[2]
- Organic Intermediate[1]
- Instrument Parts & Accessories[3]
- Test Tube[1]
- Ultrasonic Cleaners[1]
- Sterilization Equipments[1]
- Educational Equipment[1]
- Ceramics[1]
- Other Home Decor[1]
- Boilers[1]
- Laboratory Thermostatic Devices[4]
- Magnifiers[1]
- Prisms[1]
- Microscopes[7]
- Telescope & Binoculars[1]
- Emergency & Clinics Apparatus[1]
- Temperature Instruments[5]
- Chemical Reagents[6]
- Contact Person : Mr. Chen YeWei
- Company Name : Guangzhou Sinosource Trade Co., Ltd.
- Tel : 86-20-83292911
- Fax : 86-20-83292962
- Address : Guangdong,Guangzhou,Room2106, 21F,BaiYun Building,BaiYun Road 111-113,YueXiu District
- Country/Region : China
- Zip : 510200
Zeeman Atomic Absorption Spectrophotometer
Zeeman Atomic Absorption Spectrophotometer
Features:
1 Dual light sources and dual atomizers (national patent), a unique integrated structure design with a high degree of user friendliness
1.1 Parallel flame and graphite furnace atomizer, without mechanical movements and changeover, ensuring long time stability and reliability
1.2 Time-sharing dual light sources, no need for changing lamps, increasing the number of analyzable elements to the maximum and reducing operation and adjustment time to the minimum
1.3 Alternate use of the shortest optical path, to reduce light energy losses
2 More powerful dual magnetic fields Zeeman background correction technology
2.1 Adopting constant magnetic field, transverse Zeeman background correction device for both flame and graphite furnace analysis, with super powerful dual atomizer high background correction capability over the whole wavelength range
2.2 Intensified flame constant magnetic field to improve the analytical sensitivity
2.3 Quasi double beam design to correct baseline drift, shorten preheating time and improve analytical accuracy
3 Integrated design of graphite furnace power supply with the main unit
3.1 Multiple shielding technology successfully decreases magnetic interference
3.2 Shortening the distance of power supply reduces power losses dramatically
3.3 Compact structure, small space requirement, easy and simple installation and moving
4 Advanced electronic design
4.1 New generation large scale integration technology with simple and reliable PC boards
4.2 New generation bus and internal network technology, enhancing the anti-interference capability of the system
5 Fully automatic operation with high accuracy
5.1 Automatic 8×2 lamp turrets, automatic adjustment of lamp current and optimize of light beam position
5.2 Automatic wavelength scanning and peak picking
5.3 Automatic spectral bandwidth changing
5.4 Automatic changeover between flame and graphite furnace operation, automatic ignition and automatic gas flow setting
6 Brand-new fully automated flameless analysis technology with high reliability
6.1 Newly designed graphite furnace and its power supply system with ultra-rapid heating, super long time stability and super high power efficiency
6.2 Intelligent fully automated sampler, with automatic working curve generation, automatic tracing and correction of liquid surface height in the sample vessel, automatic long term memorizing of the sampling probe position
7 Perfect safety protection measures
7.1 Alarm and automatic safety protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system
7.2 Monitoring, alarm and protection function to insufficient protective gas pressure and cooling water supply in graphite furnace system
7.3 Cooling wate monitoring and protection in magnetic field system
7.4 Drain tube water seal monitoring and alarm
8 User friendly operation software
8.1 Convenient, friendly and reliable AAS software under Windows XP operation system
8.2 Quick setting, automatic adjustment and automatic optimization of instrument parameters
8.3 Safety monitoring, quick prompt ad protection
8.4 Intelligent analytical quality control, precision control, standard sample check and Spike check functions
8.5 User selectable analytical report formats
Main Specification | Wavelength range | 190-900nm |
Wavelength accuracy | ±0.5nm | |
Resolution | Better than 0.3nm. | |
Baseline stability | 0.005A/30min | |
Light Source | Lamp turret | Automatic 8×2 lamp turrets (Two high performance hollow cathode lamps can be mounted on each turret); |
Lamp current | 0~15mA | |
Lamp power supply mode | 200Hz narrow square wave pulse | |
Optical System | Monochomator | Czerny-Turner type |
Grating | 1800 l/mm | |
Focal length | 430mm | |
Blazed Wavelength | 250nm | |
Spectral Bandwidth | Flame mode:0.2nm, 0.4nm, 0.8nm, 1.6nm | |
Graphite furnace mode: 0.2,0.4, 1.2nm |
Zeeman Atomic Absorption Spectrophotometer